A comparison of the determination of the rennet coagulation properties of bovine milk

Authors

  • Roman Pytel Mendel University in Brno, Faculty of AgriSciences, Department of Food Technology, Zemědělská 1, 613 00 Brno
  • Květoslava Šustová Mendel University in Brno, Faculty of AgriSciences, Department of Food Technology, Zemědělská 1, 613 00 Brno
  • Vojtěch Kumbár Mendel University in Brno, Faculty of AgriSciences, Department of Technology and Automobile Transport, Zemědělská 1, 613 00 Brno
  • Šárka Nedomová Mendel University in Brno, Faculty of AgriSciences, Department of Food Technology, Zemědělská 1, 613 00 Brno

DOI:

https://doi.org/10.5219/604

Keywords:

rennet coagulation time, nephelo-turbidimetry, bovine milk, calcium chloride

Abstract

The aim of the work was compared of two different methods (the visual method and the nephelo turbidimetry method) for determination of rennet coagulation time. It was observed the effect of heat treatment of milk; types of rennet and addition of different amount of CaCl2 into the pasteurized milk. It was used two different chymosin rennet. For the visual method was milk sample (100 mL) equilibrated at 35 °C, 1 mL of rennet was added into milk and was measured the time required for the first visible flakes (visual method). For the determination rennet coagulation time by nephelo-turbidimetry was removed part of milk with rennet and placed into nephelo-turbidimetry. Milk had a titratable acidity in the range from 6.5 to 7.0 °SH, average pH of milk was 6.68. Dry matter content was in range from 12.351 to 13.142%. The average content of protein by Kjeldahl was 3.14%, fat by Gerber 4.34%, lactose by polarimetry 4.68% and calcium content 1.1%. The pasteurized milk had the worst rennet coagulation time about 32 s compared to the raw milk. The difference coagulation time between milk with addition of 20 µL CaCl2 and 40 µL CaCl2 was in range 21 s to 26 s by visual method. The difference coagulation time between milk with addition of 20 µL CaCl2 and 40 µL CaCl2 was 15 s by nephelo-turbidimetry method. There occurred statistically non-significant differences in most of the measurements, comparing the visual and the nephelo-turbidimetric method. The heat treatment, addition of CaCl2 and using of different rennet had an influence on the curd category. It was obtained, that using nephelo-turbidimetry shown objective results for measuring the rennet coagulation time contrary the subjective visual method. Further, the results obtained by nephelo-turbidimetry are accurate and determined with the lower variation.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

References

Bittante, G. 2011. Modeling rennet coagulation time and curd firmness of milk. Journal of Dairy Science, vol. 94, no. 12, p. 5821-5832. https://doi.org/10.3168/jds.2011-4514 DOI: https://doi.org/10.3168/jds.2011-4514

Bujko, J., Kocman, R., Žitný, J., Trakovická, A., Hrnčár, C. 2011. Analyse of traits of milk production in dairy cows. Potravinarstvo, vol. 5, no. 1, p. 5-9. https://doi.org/10.5219/93 DOI: https://doi.org/10.5219/93

Castillo, M. 2006. Cutting time prediction methods in cheese making. In Heldman, D. R., Moraru, C. I. Encyclopedia of Agricultural, Food, and Biological Engineering. 2nd ed. Boca Raton: CRC Press. p. 1-7. ISBN 13: 9781439811115

Čejna, V., Přibyla, L. 2006. Porovnání vizuální a nefelo-turbidimetrické metody pro měření syřitelnosti mléka (Comparison visual and nephelo-turbidimetry methods for rennet coagulation time of milk). Den mléka 2006. Praha: Česká zemědělská univerzita v Praze, p. 110-111. ISBN:

-213-14898-2.

Chládek, G., Čejna, V. 2005. Měření syřitelnosti mléka pomocí nefeloturbidimetrického snímače (A measurement of rennet coagulation time by nephelo-turbidimetry). Mléko a sýry 2005. Praha: Česká společnost chemická, p. 127-130. ISBN: 80-86238-48-2.

Czech state standart No 57 0530. 1974. Metody zkoušení mléka a tekutých mléčných výrobků (Methods for testing of milk and milk products), Praha: Vydavatelství Úřadu pro normalizaci a měření, 108 p.

EN ISO 8968-1:2002. Mléko - Stanovení obsahu dusíku. Část 1, Metoda dle Kjeldahla (Milk and milk products - Determination of nitrogen content. Part 1, Kjeldahl method and crude protein calculation), Praha: Český normalizační institut, 16 p.

Erdem, Y. K. 1997. The affect of calcium chloride concentration and pH on the clotting time during the renneting of milk. Gida, vol. 22, no. 6, p. 449-455.

Fox, F., McSweeney, P. L. H., Cohan, T. M., Guinee, T. P. 2004. Cheese Chemistry, Physics and Microbiology. Volume 1. 3rd ed. Elsevier Ltd., Oxford. 617 p. ISBN-13: 978-0122636523

Fuquay, J. W., Fox, P. F., McSweeney, P. L. H. 2011. Encyclopedia of Dairy Sciences. 2nd ed. Amsterdam: Academic Press. 923 p. ISBN-13: 9780123744029.

Hardy, J., Fanni, J. 1981. Application of reflection photometry to the measurement of milk coagulation. Journal of Food Science, vol. 46, no. 6, p. 1956-1957. https://doi.org/10.1111/j.1365-2621.1981.tb04531.x DOI: https://doi.org/10.1111/j.1365-2621.1981.tb04531.x

Herbert, S., Riaublanc, A., Bouchet, B., Gallant, D. J., Dufour, E. 1999. Fluorescence spectroscopy investigation of acid- or rennetinduced coagulation of milk. Journal of Dairy Science, vol. 82, no. 10, p. 2056-2062. https://doi.org/10.3168/jds.S0022-0302(99)75446-9 DOI: https://doi.org/10.3168/jds.S0022-0302(99)75446-9

ISO 2446:2008. Mléko - Stanovení obsahu tuku (Milk - Determination of fat content), Praha: Úřad pro technickou normalizaci, metrologii a státní zkušebnictví, 16 p.

ISO 6731:2010. Mléko, smetana a zahuštěné neslazené mléko - Stanovení obsahu celkové sušiny (Milk, cream and evaporated milk - Determination of total solids content), Praha: Úřad pro technickou normalizaci, metrologii a státní zkušebnictví, 12 p.

Klandar, A. H., Lagaude, A., Chevalier-Lucia, D. 2007. Assessment of the rennet coagulation of skim milk: A comparison of methods. International Dairy Journal, vol. 17, no. 10, p. 1151-1160. https://doi.org/10.1016/j.idairyj.2007.03.005 DOI: https://doi.org/10.1016/j.idairyj.2007.03.005

Korolczuk, J., Maubois, J. L. 1988. Effect of pH, calcium concentration and temperature on the evolution of the refractometric signal produced during rennet coagulation of milk. Journal of Dairy Research, vol. 55, p. 81-88. DOI: https://doi.org/10.1017/S0022029900025875

Kuchtík, J., Šustová, K., Urban, T., Zapletal, D. 2008. Effect of the stage of lactation on milk composition, its properties and the quality of rennet curdling in East Friesian ewes. Czech Journal of Animal Science, vol. 53, no. 2, p. 55-63. ISSN: 12121819 DOI: https://doi.org/10.17221/333-CJAS

Law, B. A., Tamime, A. 2010. Technology of cheesemaking. 2nd ed. Malden, MA: Blackwell, 482 p. ISBN-13: 978-140-5182-980.

Lucey, J. A., Fox, P. F. 1993. Importance of Calcium and Phosphate in Cheese Manufacture: A Review. Journal of Dairy Science, vol. 76, no. 6, p. 1714-1724. https://doi.org/10.3168/jds.S0022-0302(93)77504-9 DOI: https://doi.org/10.3168/jds.S0022-0302(93)77504-9

Marshall, R. J., Hatfield, D. S., Green, M. L. 1982. Assessment of two instruments for continuous measurement of the curd-firming of renneted milk. Journal of Dairy Research, vol. 49, p. 127-135. https://doi.org/10.1017/S0022029900022202 DOI: https://doi.org/10.1017/S0022029900022202

Maxcy, R. B., Price, W. V., Irvine, D. M. 1955. Improving curd-forming properties of homogenized milk. Journal of Dairy Science, vol. 38, p. 80-86. DOI: https://doi.org/10.3168/jds.S0022-0302(55)94941-9

McMahon, D. J., Brown, R. J. 1982. Evaluation of formagraph for comparing rennet solutions. Journal of Dairy Science, vol. 65, no. 8, p. 1639-1642. https://doi.org/10.3168/jds.S0022-0302(82)82390-4 DOI: https://doi.org/10.3168/jds.S0022-0302(82)82390-4

Nájera, A. I., De Renobales, M., Barron, L. J. R. 2003. Effects of pH, temperature, CaCl2 and enzyme concentrations on the rennet-clotting properties of milk: a multifactorial study. Food Chemistry, vol. 80, no. 3, p. 345-352. https://doi.org/10.1016/S0308-8146(02)00270-4 DOI: https://doi.org/10.1016/S0308-8146(02)00270-4

Nassar, G., Nongaillard, B., Noel, Y. 2001. Monitoring of milk gelation using a low-frequency ultrasonic technique. Journal of Food Engineering, vol. 48, no. 4, p. 351-359. https://doi.org/10.1016/S0260-8774(00)00178-3 DOI: https://doi.org/10.1016/S0260-8774(00)00178-3

O'Callaghan, D. J., O'Donnell, C. P., Payne, F. A. 2000. On-line sensing techniques for coagulum setting in renneted milks. Journal of Food Engineering, vol. 43, no. 3, p. 155-165. https://doi.org/10.1016/S0260-8774(99)00145-4 DOI: https://doi.org/10.1016/S0260-8774(99)00145-4

Roginski, H., Fuquay, J. W., Fox, P. 2003. Encyclopedia of Dairy Sciences: Volume 1. New York: Academic Press, 557 p. ISBN-13: 0122272358.

Sbodio, O. A., Revelli, G. R. 2012. Milk's coagulation. Development of a device for online "monitoring" of the process. Progress made in Argentina. Revista de Investigaciones Agropecuarias, vol. 38.

Sojková, K., Hanuš, O., Dufek, A., Kopecký, J., Jedelská, R. 2011. Srovnání nefelometricky a tradičně stanovené koagulace proteinů syrového kravského mléka jako technologické vlastnosti (Compared nephelometry and traditionally determined protein coagulation of raw cow's milk as the technological properties). Výzkum v chovu skotu / Cattle Research, vol. 1, p. 52-59.

Sommer, H. H., Matsen, H. 1935. The relation of mastitis to rennet coagulability and curd strength of milk. Journal of Dairy Science, vol. 18, no. 11, p. 741-749. https://doi.org/10.3168/jds.S0022-0302(35)93196-4 DOI: https://doi.org/10.3168/jds.S0022-0302(35)93196-4

Wade, T., Beattie, J. K. 1998. situ observation of rennetting by electroacoustics. Milchwissenschaft, vol. 53, no. 9, p. 490-493.

Wolfschoon-Pombo, A. F. 1997. Influence of calcium chloride addition to milk on the cheese yield. International Dairy Journal, vol. 7, no. 4, p. 249-254 https://doi.org/10.1016/S0958-6946(97)00005-8 DOI: https://doi.org/10.1016/S0958-6946(97)00005-8

Yuksel, Z. 2013. Determination of rennet clotting time by texture analysis method. Food and Nutrition Sciences, vol. 4, no. 11, p. 1108-1113. https://doi.org/10.4236/fns.2013.411144 DOI: https://doi.org/10.4236/fns.2013.411144

Downloads

Published

2016-07-05

How to Cite

Pytel, R. ., Šustová, K. ., Kumbár, V. ., & Nedomová, Šárka . (2016). A comparison of the determination of the rennet coagulation properties of bovine milk. Potravinarstvo Slovak Journal of Food Sciences, 10(1), 366–371. https://doi.org/10.5219/604